96 Tests
EKU06946
848€
6-11 Business days
Protein Tyrosine Phosphatase Receptor Type J
CD148, PTPR-J, DEP1, HPTPeta, R-PTP-ETA, SCC1, Protein-tyrosine phosphatase eta, Density-enhanced phosphatase 1
Homo sapiens (Human)
Tissue homogenates, Cell lysates and other biological fluids.
0.312-20 ng/mL
0.117 ng/mL
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Protein Tyrosine Phosphatase Receptor Type J were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Protein Tyrosine Phosphatase Receptor Type J were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV
Colorimetric
3 hours
For research use only. Not for diagnostic procedures.
Double-antibody Sandwich
Ice packs
Short term: 4°C; Long term: see manual.
The Stop Solution is acidic. Do not allow to contact skin or eyes.
Use Human Protein Tyrosine Phosphatase Receptor Type J (PTPRJ) ELISA Kit before 8 months
This assay has high sensitivity and excellent specificity for detection of Protein Tyrosine Phosphatase Receptor Type J
No significant cross-reactivity or interference between Protein Tyrosine Phosphatase Receptor Type J and analogues was observed.
No significant cross-reactivity or interference between Protein Tyrosine Phosphatase Receptor Type J and analogues was observed.
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.
Signal transduction, CD & Adhesion molecule, Tumor immunity, Infection immunity
E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.
ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED
The receptors are ligand binding factors of type 1, 2 or 3 and protein-molecules that receive chemical-signals from outside a cell. When such chemical-signals couple or bind to a receptor, they cause some form of cellular/tissue-response, e.g. a change in the electrical-activity of a cell. In this sense, am olfactory receptor is a protein-molecule that recognizes and responds to endogenous-chemical signals, chemokinesor cytokines e.g. an acetylcholine-receptor recognizes and responds to its endogenous-ligand, acetylcholine. However, sometimes in pharmacology, the term is also used to include other proteins that are drug-targets, such as enzymes, transporters and ion-channels.