Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit

Size

96 Tests

Catalog No

EKU02080

Price

885€

Estimated Turnaround Time

6-11 Business days

Target Name

Acid Phosphatase 2, Lysosomal

Target's alterntive name

Lysosomal Acid Phosphatase

Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit

Species Reactivity

Homo sapiens (Human)

Sample Type

Serum, Plasma, Tissue homogenates and other biological fluids.

Detection Range

62.5-4000 pg/mL

Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit

Sensitivity

24.2 pg/mL

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Acid Phosphatase 2, Lysosomal were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Acid Phosphatase 2, Lysosomal were tested on 3 different plates, 8 replicates in each plate.CV (%) = SD/meanX100;Intra-Assay: CV

Detection Method

Colorimetric

Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit

Assay Time

3 hours

Application

For research use only. Not for diagnostic procedures.

Assay Type

Double-antibody Sandwich

Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit

Shipping Conditions

Ice packs

Storage Temperature

Short term: 4°C; Long term: see manual.

Precaution of Use

The Stop Solution is acidic. Do not allow to contact skin or eyes.

Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit

Shelf life

Use Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit before 8 months

Specificity

This assay has high sensitivity and excellent specificity for detection of Acid Phosphatase 2, Lysosomal

Cross Activity

No significant cross-reactivity or interference between Acid Phosphatase 2, Lysosomal and analogues was observed.

Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit

Test Principle

No significant cross-reactivity or interference between Acid Phosphatase 2, Lysosomal and analogues was observed.

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Quality Systems

The kit is manufactured at ISO 9001 and ISO 13485 certified facilities.

Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit

Research Area

Enzyme & Kinase

Properties

E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,E05 478 566 350 170 or Enzyme-Linked Immunosorbent Assays,Human proteins, cDNA and human recombinants are used in human reactive ELISA kits and to produce anti-human mono and polyclonal antibodies. Modern humans (Homo sapiens, primarily ssp. Homo sapiens sapiens). Depending on the epitopes used human ELISA kits can be cross reactive to many other species. Mainly analyzed are human serum, plasma, urine, saliva, human cell culture supernatants and biological samples.

Test

ELISA Enzyme-linked immunosorbent assays Code 90320007 SNOMED

Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit
Human Acid Phosphatase 2, Lysosomal (ACP2) ELISA Kit